{"id":29199,"date":"2026-11-12T01:37:26","date_gmt":"2026-11-12T01:37:26","guid":{"rendered":"https:\/\/unnes.ac.id\/ft\/?p=29199"},"modified":"2026-11-16T03:03:46","modified_gmt":"2026-11-16T03:03:46","slug":"unnes-electrical-engineering-students-develop-aiot-based-smart-harmonic-analyzer-for-power-quality-monitoring","status":"publish","type":"post","link":"https:\/\/unnes.ac.id\/ft\/2026\/11\/12\/unnes-electrical-engineering-students-develop-aiot-based-smart-harmonic-analyzer-for-power-quality-monitoring\/","title":{"rendered":"UNNES Electrical Engineering Students Develop AIoT-Based Smart Harmonic Analyzer for Power Quality Monitoring"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>SEMARANG<\/strong> \u2014 Three Electrical Engineering students from the Faculty of Engineering, Universitas Negeri Semarang (FT UNNES)\u2014Rakha Alviano Syaputra, Raditya Wahyu Pratomo, and Ellena Nayla Firdausi\u2014unveiled <em>Smart Harmonic Analyzer<\/em>, an electrical power quality monitoring instrument powered by the Artificial Intelligence of Things (AIoT), during the EXPO Capstone exhibition at Building E11, FT UNNES, on Wednesday (November 11, 2026).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The prototype was engineered to address power quality degradation caused by nonlinear electrical loads, which are increasingly prevalent in modern electronic devices and industrial machinery. Nonlinear loads generate harmonic distortions that degrade electrical efficiency, cause overheating in conductors and transformers, and shorten equipment lifespans. While commercial harmonic analyzers exist, they are often prohibitively expensive and lack integrated cloud or AI diagnostic capabilities.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/unnes.ac.id\/ft\/wp-content\/uploads\/sites\/9\/2026\/11\/Smart-Harmonic-Analyzer-1-1-1024x683.jpeg\" alt=\"\" class=\"wp-image-29200\" srcset=\"https:\/\/unnes.ac.id\/ft\/wp-content\/uploads\/sites\/9\/2026\/11\/Smart-Harmonic-Analyzer-1-1-1024x683.jpeg 1024w, https:\/\/unnes.ac.id\/ft\/wp-content\/uploads\/sites\/9\/2026\/11\/Smart-Harmonic-Analyzer-1-1-300x200.jpeg 300w, https:\/\/unnes.ac.id\/ft\/wp-content\/uploads\/sites\/9\/2026\/11\/Smart-Harmonic-Analyzer-1-1-768x512.jpeg 768w, https:\/\/unnes.ac.id\/ft\/wp-content\/uploads\/sites\/9\/2026\/11\/Smart-Harmonic-Analyzer-1-1.jpeg 1500w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">To provide a more accessible and intelligent alternative, the team designed a dedicated data acquisition architecture centered on an <strong>ESP32<\/strong> microcontroller integrated with a <strong>ZMPT101B<\/strong> voltage sensor, an <strong>SCT-013-030<\/strong> current sensor, and an <strong>ADS1115<\/strong> Analog-to-Digital Converter (ADC) module. Additionally, a <strong>PZEM-004T<\/strong> energy meter was incorporated into the system as a reference benchmark to validate measurement accuracy.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Captured voltage and current waveforms are processed using Digital Signal Processing (DSP) techniques, specifically the Fast Fourier Transform (FFT), to isolate the fundamental frequency and identify harmonic components. The system evaluates key power quality metrics\u2014including harmonic amplitude, harmonic ratio, Root Mean Square (RMS) values, and Signal-to-Noise Ratio (SNR)\u2014to provide a comprehensive assessment of electrical grid health.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Processed data is transmitted in real time via the <strong>MQTT<\/strong> communication protocol to a <strong>FastAPI<\/strong>-based backend and rendered on an intuitive web monitoring dashboard. Enhancing its analytical capabilities, the platform integrates a <strong>Random Forest<\/strong> Machine Learning model to automatically classify connected electrical load types, alongside a <strong>Fuzzy Logic<\/strong> inference engine that evaluates overall power quality and triggers automated alerts when anomalies occur.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">From an engineering efficiency standpoint, the team completed the prototype on September 14, 2026, following a 30-day development cycle encompassing hardware assembly, DSP implementation, machine learning integration, and calibration. Constructed with a total budget of IDR 700,000 (Rp700,000), the device demonstrates that sophisticated harmonic analysis instrumentation can be engineered domestically at a fraction of commercial costs.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" data-id=\"29201\" src=\"https:\/\/unnes.ac.id\/ft\/wp-content\/uploads\/sites\/9\/2026\/11\/Smart-Harmonic-Analyzer-2-1-768x1024-1.jpeg\" alt=\"\" class=\"wp-image-29201\" srcset=\"https:\/\/unnes.ac.id\/ft\/wp-content\/uploads\/sites\/9\/2026\/11\/Smart-Harmonic-Analyzer-2-1-768x1024-1.jpeg 768w, https:\/\/unnes.ac.id\/ft\/wp-content\/uploads\/sites\/9\/2026\/11\/Smart-Harmonic-Analyzer-2-1-225x300.jpeg 225w, https:\/\/unnes.ac.id\/ft\/wp-content\/uploads\/sites\/9\/2026\/11\/Smart-Harmonic-Analyzer-2-1-600x800.jpeg 600w, https:\/\/unnes.ac.id\/ft\/wp-content\/uploads\/sites\/9\/2026\/11\/Smart-Harmonic-Analyzer-2-1.jpeg 996w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" data-id=\"29235\" src=\"https:\/\/unnes.ac.id\/ft\/wp-content\/uploads\/sites\/9\/2026\/11\/Smart-Harmonic-Analyzer-5-1-768x1024-1.jpeg\" alt=\"\" class=\"wp-image-29235\" srcset=\"https:\/\/unnes.ac.id\/ft\/wp-content\/uploads\/sites\/9\/2026\/11\/Smart-Harmonic-Analyzer-5-1-768x1024-1.jpeg 768w, https:\/\/unnes.ac.id\/ft\/wp-content\/uploads\/sites\/9\/2026\/11\/Smart-Harmonic-Analyzer-5-1-225x300.jpeg 225w, https:\/\/unnes.ac.id\/ft\/wp-content\/uploads\/sites\/9\/2026\/11\/Smart-Harmonic-Analyzer-5-1-600x800.jpeg 600w, https:\/\/unnes.ac.id\/ft\/wp-content\/uploads\/sites\/9\/2026\/11\/Smart-Harmonic-Analyzer-5-1.jpeg 960w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Showcased at FT UNNES&#8217;s EXPO Capstone, the <em>Smart Harmonic Analyzer<\/em> directly advances <strong>SDG 9 (Industry, Innovation, and Infrastructure)<\/strong> by fostering resilient energy infrastructure and accessible AIoT instrumentation. Through practical, high-impact applied research, UNNES Electrical Engineering students continue to drive technological innovation aimed at enhancing electrical infrastructure reliability and industrial efficiency.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>SEMARANG \u2014 Three Electrical Engineering students from the Faculty of Engineering, Universitas Negeri Semarang (FT UNNES)\u2014Rakha Alviano Syaputra, Raditya Wahyu Pratomo, and Ellena Nayla Firdausi\u2014unveiled Smart Harmonic Analyzer, an electrical power quality monitoring instrument powered by the Artificial Intelligence of Things (AIoT), during the EXPO Capstone exhibition at Building E11, FT UNNES, on Wednesday (November [&hellip;]<\/p>\n","protected":false},"author":17,"featured_media":29194,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"rs_blank_template":"","rs_page_bg_color":"","slide_template_v7":"","footnotes":""},"categories":[12,356],"tags":[394],"class_list":["post-29199","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-fakultas-teknik-eng","category-sdg9","tag-unnessdgs09"],"_links":{"self":[{"href":"https:\/\/unnes.ac.id\/ft\/wp-json\/wp\/v2\/posts\/29199","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/unnes.ac.id\/ft\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/unnes.ac.id\/ft\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/unnes.ac.id\/ft\/wp-json\/wp\/v2\/users\/17"}],"replies":[{"embeddable":true,"href":"https:\/\/unnes.ac.id\/ft\/wp-json\/wp\/v2\/comments?post=29199"}],"version-history":[{"count":5,"href":"https:\/\/unnes.ac.id\/ft\/wp-json\/wp\/v2\/posts\/29199\/revisions"}],"predecessor-version":[{"id":29241,"href":"https:\/\/unnes.ac.id\/ft\/wp-json\/wp\/v2\/posts\/29199\/revisions\/29241"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/unnes.ac.id\/ft\/wp-json\/wp\/v2\/media\/29194"}],"wp:attachment":[{"href":"https:\/\/unnes.ac.id\/ft\/wp-json\/wp\/v2\/media?parent=29199"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/unnes.ac.id\/ft\/wp-json\/wp\/v2\/categories?post=29199"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/unnes.ac.id\/ft\/wp-json\/wp\/v2\/tags?post=29199"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}